Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.352
Filtrar
1.
Artigo em Russo | MEDLINE | ID: mdl-38549407

RESUMO

OBJECTIVE: To evaluate mechanical strength of three methods of polymethyl methacrylate skull implant fixation in two experimental models. MATERIAL AND METHODS: The first experiment was performed on a plastic model that was as close as possible to bone in structural characteristics. The second experiment was performed on a biological specimen (a ram's head). We assessed the quality of implant fixation to bone window edges by craniofixes, ties and microscrews and lateral intercortical screws. RESULTS: Craniofixes are feasible for small flat flaps, but not advisable for wide highly curved implants. They are also the most expensive method of fixation. Implant fixation by ties and microscrews is a universal method comparable in price to craniofix. Lateral intercortical fixation is effective both for small flat implants and wide implants with large curvature. However, this method is not always applicable. CONCLUSION: Combined fixation by lateral intercortical screws and ties allows for the most effective fixation while reducing the overall price of consumables.


Assuntos
Polimetil Metacrilato , Titânio , Masculino , Animais , Ovinos , Polimetil Metacrilato/química , Crânio/cirurgia , Próteses e Implantes , Craniotomia/métodos
2.
ACS Biomater Sci Eng ; 10(4): 2398-2413, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38477550

RESUMO

In vertebroplasty and kyphoplasty, bioinert poly(methyl methacrylate) (PMMA) bone cement is a conventional filler employed for quick stabilization of osteoporotic vertebral compression fractures (OVCFs). However, because of the poor osteointegration, excessive stiffness, and high curing temperature of PMMA, the implant loosens, the adjacent vertebrae refracture, and thermal necrosis of the surrounding tissue occurs frequently. This investigation addressed these issues by incorporating the small intestinal submucosa (SIS) into PMMA (SIS-PMMA). In vitro analyses revealed that this new SIS-PMMA bone cement had improved porous structure, as well as reduced compressive modulus and polymerization temperature compared with the original PMMA. Furthermore, the handling properties of SIS-PMMA bone cement were not significantly different from PMMA. The in vitro effect of PMMA and SIS-PMMA was investigated on MC3T3-E1 cells via the Transwell insert model to mimic the clinical condition or directly by culturing cells on the bone cement samples. The results indicated that SIS addition substantially enhanced the proliferation and osteogenic differentiation of MC3T3-E1 cells. Additionally, the bone cement's biomechanical properties were also assessed in a decalcified goat vertebrae model with a compression fracture, which indicated the SIS-PMMA had markedly increased compressive strength than PMMA. Furthermore, it was proved that the novel bone cement had good biosafety and efficacy based on the International Standards and guidelines. After 12 weeks of implantation, SIS-PMMA indicated significantly more osteointegration and new bone formation ability than PMMA. In addition, vertebral bodies with cement were also extracted for the uniaxial compression test, and it was revealed that compared with the PMMA-implanted vertebrae, the SIS-PMMA-implanted vertebrae had greatly enhanced maximum strength. Overall, these findings indicate the potential of SIS to induce efficient fixation between the modified cement surface and the host bone, thereby providing evidence that the SIS-PMMA bone cement is a promising filler for clinical vertebral augmentation.


Assuntos
Fraturas por Compressão , Fraturas da Coluna Vertebral , Humanos , Cimentos Ósseos/farmacologia , Cimentos Ósseos/química , Polimetil Metacrilato/farmacologia , Polimetil Metacrilato/química , Osteogênese , Fraturas da Coluna Vertebral/cirurgia , Coluna Vertebral
3.
Int J Mol Sci ; 25(5)2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38474234

RESUMO

Developmental engineering (DE) involves culturing various cells on modular scaffolds (MSs), yielding modular tissues (MTs) assembled into three-dimensional (3D) tissues, mimicking developmental biology. This study employs an integrated approach, merging experimental and mathematical methods to investigate the biological processes in MT cultivation and assembly. Human dermal fibroblasts (HDFs) were cultured on tissue culture plastics, poly(lactic acid) (PLA) discs with regular open structures, or spherical poly(methyl methacrylate) (PMMA) MSs, respectively. Notably, HDFs exhibited flattened spindle shapes when adhered to solid surfaces, and complex 3D structures when migrating into the structured voids of PLA discs or interstitial spaces between aggregated PMMA MSs, showcasing coordinated colonization of porous scaffolds. Empirical investigations led to power law models simulating density-dependent cell growth on solid surfaces or voids. Concurrently, a modified diffusion model was applied to simulate oxygen diffusion within tissues cultured on solid surfaces or porous structures. These mathematical models were subsequently combined to explore the influences of initial cell seeding density, culture duration, and oxygen diffusion on MT cultivation and assembly. The findings underscored the intricate interplay of factors influencing MT design for tissue assembly. The integrated approach provides insights into mechanistic aspects, informing bioprocess design for manufacturing MTs and 3D tissues in DE.


Assuntos
Engenharia Tecidual , Tecidos Suporte , Humanos , Tecidos Suporte/química , Engenharia Tecidual/métodos , Polimetil Metacrilato/química , Poliésteres , Oxigênio
4.
J Mech Behav Biomed Mater ; 154: 106501, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38531182

RESUMO

OBJECTIVE: The influence of various aging protocols, representing and accelerating influences present in the dental context, on possible changes in the microstructure and mechanical properties of thermoplastics was investigated. In order to minimize the complexity of the systems, first pure polymers and then later the equivalent dental polymeric materials were analyzed. MATERIALS AND METHODS: Pure polymers (Poly(methyl methacrylate) - PMMA, Polyoxymethylene homopolymer - POM-H, Polyether ether ketone - PEEK, Nylon 12 - PA12, Polypropylene - PP) were analyzed before as well as after applying different aging protocols relevant to the oral environment (ethanol, thermocycling, alkaline and acidic setting) by differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). The thermoanalytical parameters used were glass transition temperature (Tg), melting peak and crystallization peak temperature (Tpm, Tpc) and decomposition behavior. In a second step selected commercially available dental products (Telio CAD - PMMAD, Zirlux Acetal - POMD, Juvora Natural Dental Disc - PEEKD) aged by the protocol that previously showed strong effects were examined and additionally tested for changes in their Vickers and Martens hardness by Mann-Whitney-U test. RESULTS: The combinations of pure polymers and viable aging protocols analyzed within this study were identified via TGA or DSC as PA12 & thermocycling, POM-H & denture cleanser/lactic acid/ethanol, PP & lactic acid. The dental polymeric materials PMMAD and POMD due to aging in lactic acid showed slight but significantly (p < 0.01) reduced Vickers and partly Martens hardness. PEEK showed the greatest material resistance within this study.


Assuntos
Benzofenonas , Mustelidae , Polimetil Metacrilato , Animais , Polimetil Metacrilato/química , Teste de Materiais , Dureza , Polímeros/química , Polietilenoglicóis/química , Cetonas/química , Etanol , Ácido Láctico , Materiais Dentários , Propriedades de Superfície
5.
PLoS One ; 19(3): e0299325, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38457423

RESUMO

PURPOSE: Vertebral compression fractures are often treated with vertebroplasty, and filling the injured vertebrae with bone cement is a key part of vertebroplasty. This meta-analysis was performed to compare the clinical efficacy and safety of mineralized collagen-polymethylmethacrylate (MC-PMMA) and polymethylmethacrylate (PMMA) bone cement in the treatment of vertebral compression fractures by vertebroplasty. METHODS: A computerized search of the published literature on mineralized collagen-polymethylmethacrylate and polymethylmethacrylate bone cement in the treatment of vertebral compression fractures was conducted in the China National Knowledge Infrastructure (CNKI), Wanfang database, PubMed, Embase, and Cochrane Library. The search was carried out from the time the database was created to March 2023 and 2 researchers independently conducted literature searches to retrieve a total of 884 studies, of which 12 were included in this meta-analysis. Cochrane systematic review methods were used to assess the quality of the literature and a meta-analysis was performed using ReviewManager 5.4 software. RESULTS: The results of the present meta-analysis showed that in postoperative adjacent vertebral fractures [OR = 0.25; 95% CI (0.15, 0.41)], postoperative cement leakage [OR = 0.45; 95% CI (0.30, 0.68)], Oswestry Disability Index (ODI) scores in the first 3 days after surgery [OR = -0.22; 95% CI (-0.42, -0.03)], ODI score at 6-12 months postoperatively [OR = -0.65; 95% CI (-0.97, -0.32)], visual analog scale (VAS) score at 6-12 months postoperatively [OR = -0.21; 95% CI (-0.46, 0.04)], and 1-year postoperative CT values [OR = 5.56; 95% CI (3.06, 8.06)], the MC-PMMA bone cement group was superior to the PMMA bone cement group. However, the differences between the two groups were not statistically different in terms of cement filling time, cement filling volume, operation time, intraoperative bleeding, hospitalization time, postoperative (<1 week, 3-6 months) vertebral body posterior convexity Cobb's angle, postoperative (<1 week, 6-12 months) vertebral body anterior margin relative height, postoperative (≤3 days, 1-3 months) pain VAS score and postoperative (1-3 months) ODI score. CONCLUSIONS: Compared with PMMA bone cement, the application of MC-PMMA bone cement is advantageous in reducing postoperative complications (adjacent vertebral fracture rate, cement leakage rate), pain relief, and functional recovery in the long-term postoperative period (>6 months), but there is still a need for more high-quality randomized controlled studies to provide more adequate evidence.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Cimentos Ósseos/uso terapêutico , Cimentos Ósseos/química , Colágeno , Fraturas por Compressão/cirurgia , Cifoplastia/métodos , Fraturas por Osteoporose/cirurgia , Dor/tratamento farmacológico , Polimetil Metacrilato/uso terapêutico , Polimetil Metacrilato/química , Fraturas da Coluna Vertebral/cirurgia , Resultado do Tratamento
6.
Colloids Surf B Biointerfaces ; 237: 113864, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522283

RESUMO

Electrospun polymer scaffolds have gained prominence in biomedical applications, including tissue engineering, drug delivery, and wound dressings, due to their customizable properties. As the interplay between cells and materials assumes fundamental significance in biomaterials research, understanding the relationship between fiber properties and cell behaviour is imperative. Nevertheless, altering fiber properties introduces complexity by intertwining mechanical and surface chemistry effects, challenging the differentiation of their individual impacts on cell behaviour. Core-shell fibers present an appealing solution, enabling the control of mechanical properties of scaffolds, flexibility in material and drug selection, efficient encapsulation, strong protection of bioactive drugs against harsh environments, and controlled, prolonged drug release. This study addresses a key challenge in core-shell fiber design related to the blending effect between core and shell polymers. Two types of fibers, PMMA and core-shell PC-PMMA, were electrospun, and thorough analyses confirmed the desired core-shell structure in PC-PMMA fibers. Surface chemistry analysis revealed PC diffusion to the PMMA shell of the core-shell fiber during electrospinning, subsequently prompting an investigation of the fiber's surface potential. Conducting cellular studies on osteoblasts by super-resolution confocal microscopy provided insights into the direct influence of interfacial polymer blending and, consequently, altered fiber surface and mechanical properties on cell focal adhesion points, bridging the gap between material attributes and cell responses in core-shell fibers.


Assuntos
Polímeros , Polimetil Metacrilato , Polímeros/química , Polimetil Metacrilato/química , Adesões Focais , Engenharia Tecidual , Materiais Biocompatíveis/química , Tecidos Suporte/química
7.
Sci Rep ; 14(1): 2831, 2024 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310102

RESUMO

The application of microfluidic devices as next-generation cell and tissue culture systems has increased impressively in the last decades. With that, a plethora of materials as well as fabrication methods for these devices have emerged. Here, we describe the rapid prototyping of microfluidic devices, using micromilling and vapour-assisted thermal bonding of polymethyl methacrylate (PMMA), to create a spheroid-on-a-chip culture system. Surface roughness of the micromilled structures was assessed using scanning electron microscopy (SEM) and atomic force microscopy (AFM), showing that the fabrication procedure can impact the surface quality of micromilled substrates with milling tracks that can be readily observed in micromilled channels. A roughness of approximately 153 nm was created. Chloroform vapour-assisted bonding was used for simultaneous surface smoothing and bonding. A 30-s treatment with chloroform-vapour was able to reduce the surface roughness and smooth it to approximately 39 nm roughness. Subsequent bonding of multilayer PMMA-based microfluidic chips created a durable assembly, as shown by tensile testing. MDA-MB-231 breast cancer cells were cultured as multicellular tumour spheroids in the device and their characteristics evaluated using immunofluorescence staining. Spheroids could be successfully maintained for at least three weeks. They consisted of a characteristic hypoxic core, along with expression of the quiescence marker, p27kip1. This core was surrounded by a ring of Ki67-positive, proliferative cells. Overall, the method described represents a versatile approach to generate microfluidic devices compatible with biological applications.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Microfluídica/métodos , Polimetil Metacrilato/química , Clorofórmio , Dispositivos Lab-On-A-Chip
8.
J Mech Behav Biomed Mater ; 150: 106258, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38000162

RESUMO

In bone tissue engineering (BTE), defects in large bones remain the greatest issue which can be addressed using bone scaffolds. In this work, blends of heat cured polymethylmethacrylate (HC PMMA) and various weight percentages of poly-ether-ketone-ketone (PEKK) (0, 2, 4, 8, and 10%) were made using a porogen leaching process. The blends were then subjected to tensile, compression and bending tests to select the optimum blend. Based on the results obtained, HC PMMA blended with 2 wt% PEKK was selected to produce the bio-porous blends. Here, the porosity was imparted using tartaric acid (C4H6O6) and sodium hydrogen carbonate (NaHCO3) as porogen leaching components. Porous blends resulted were then reinforced with a nano titanium dioxide powder (nTiO2) at different weight percentages of (0, 1, 3, and 5). The results showed that porous composites made of (HC PMMA: 2 wt% PEKK) blend reinforced with 5 wt % nTiO2 exhibit the highest strength values under various loadings. The FTIR identified the functional groups of the bone scaffold components. The mean pore size and pore depth were measured using atomic force microscopy (AFM) analysis and the values are 92.6 nm and 42.78 nm, respectively. The good distribution of the PEKK and nTiO2 within the HC PMMA and the uniform porous structure with multi-scale pores between 535 nm and 1.187 mm were confirmed by the AFM data and SEM images, respectively. This research expected that the porous composite (HC PMMA: 2% PEKK: 5% nTiO2) is a good candidate for bone scaffold applications.


Assuntos
Cetonas , Polimetil Metacrilato , Polimetil Metacrilato/química , Cetonas/química , Éter , Temperatura Alta , Engenharia Tecidual , Porosidade , Etil-Éteres , Éteres , Tecidos Suporte/química
9.
Oper Dent ; 49(1): 76-83, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38019216

RESUMO

OBJECTIVE: To evaluate the influence of post-cure heat treatments (PCHT) on Knoop microhardness (KHN) and color change of bis-acryl composite resin (Protemp 4 - 3M ESPE, USA and PrimmaArt - FGM, Brazil) and chemically activated acrylic resins (Dencôr - Clássico, Brazil, and Duralay - Cotia, Brazil). METHODS AND MATERIALS: Specimens (12×1 mm) were prepared for each material (n=10/group). Thirty minutes after curing, the specimens were subjected to PCHT for 10 minutes at 70°, 100°, or 130°C. The control group was kept at room temperature (24°C) for the same amount of time. KHN was analyzed 24 hours after PCHT (n=10). Following Commission Internationale de l'Éclairage (CIE) Delta E 2000 (CIEDE2000 [ΔE00]), color measurements were obtained at three time points: 1. after polymerization; 2. after PCHT; and 3. after 30 days of storage in water, coffee, or red wine. Data for each material were analyzed by one-way analysis of variance (ANOVA) (p<0.05). RESULTS: The PCHT at 130°C produced the highest KHN values. Except for the 70°C groups from Dencôr and Protemp, all PCHTs increased the initial color values (p>0.05). In general, chemically activated acrylic resins showed an increase in color stability when subjected to PCHT (p>0.05). For bis-acryl composite resin, PCHT did not influence color stability (p<0.05). CONCLUSION: Overall, the results showed that PCHT increased the tested materials' color changes and Knoop microhardness. However, except for PCHT at 130°C in Duralay, the color changes remained within acceptable values. The PCHT treatment resulted in better color stability for most of the composite resins studied.


Assuntos
Resinas Compostas , Temperatura Alta , Resinas Compostas/uso terapêutico , Resinas Compostas/química , Resinas Acrílicas/química , Polimetil Metacrilato/química
10.
Int J Biol Macromol ; 256(Pt 2): 128214, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37992928

RESUMO

In this study, a novel magnetic macroporous chitin microsphere (MMCM) was developed for enzyme immobilization. Chitin nanofibers were prepared and subsequently subjected to self-assembly with magnetic nanoparticles and PMMA (polymethyl methacrylate). Following this, microspheres were formed through spray drying, achieving a porous structure through etching. The MMCM serves as an effective support for immobilizing enzymes, allowing for their covalent immobilization both on the microsphere's surface and within its pores. The substantial surface area resulting from the porous structure leads to a 2.1-fold increase in enzyme loading capacity compared to non-porous microspheres. The MMCM enhances stability of the immobilized enzymes under various pH and temperature conditions. Furthermore, after 20 days of storage at 4 °C, the residual activity of the immobilized enzyme was 2.93 times that of the free enzyme. Even after being recycled 10 times, the immobilized enzyme retained 56.7 % of its initial activity. It's noteworthy that the active sites of the enzymes remained unchanged after immobilization using the MMCM, and kinetic analysis revealed that the affinity of the immobilized enzymes rivals that of the free enzymes.


Assuntos
Quitina , Enzimas Imobilizadas , Enzimas Imobilizadas/química , Microesferas , Quitina/química , Estabilidade Enzimática , Cinética , Concentração de Íons de Hidrogênio , Polimetil Metacrilato/química , Temperatura , Fenômenos Magnéticos
11.
J Prosthodont Res ; 68(1): 156-165, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37211413

RESUMO

PURPOSE: This study aimed to synthesize heat-cured poly(methyl methacrylate) (PMMA) acrylic formulated with copper nanoparticles (nCu) for producing dentures with antimicrobial properties and ability to prevent denture stomatitis (DS). METHODS: nCu/PMMA nanocomposites were prepared through in situ formation of nCu into methyl methacrylate (MMA). The fabricated material was characterized using scanning electron microscopy, spectroscopy (energy-dispersive X-ray, attenuated total reflectance-Fourier-transform infrared, and X-ray photoelectron spectroscopy), X-ray diffraction analysis, and mechanical flexural tests (ISO 20795-1:2008). Antimicrobial activity against Candida albicans and oral bacteria was determined. MTS assay (ISO 10993-5:2009) and copper release experiments were conducted to assess cytotoxicity. In the clinical trial, participants wearing nCu/PMMA (n=25) and PMMA (n=25) dentures were compared; specifically, DS incidence and severity and Candida species proliferation were assessed for 12 months. Data were analyzed using analysis of variance with Tukey's post hoc test (α=0.05). RESULTS: nCu/PMMA nanocomposite loaded with 0.045% nCu exhibited the maximum antimicrobial activity against C. albicans and other oral bacteria without producing cytotoxicity in the wearer. nCu/PMMA dentures retained their mechanical and aesthetic properties as well as inhibited the growth of Candida species on both denture surface and patient palate. DS incidence and severity were lower in the nCu/PMMA denture group than in the PMMA denture group. CONCLUSIONS: PMMA acrylic produced with copper nanotechnology is antimicrobial, biocompatible, and aesthetic and can reduce DS incidence. Thus, this material may act as a novel preventive alternative for oral infections associated with denture use.


Assuntos
Anti-Infecciosos , Nanopartículas , Humanos , Polimetil Metacrilato/química , Cobre , Bases de Dentadura/microbiologia , Anti-Infecciosos/farmacologia , Nanopartículas/química , Candida albicans , Teste de Materiais
12.
J Biomater Sci Polym Ed ; 35(3): 345-363, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38113176

RESUMO

Carbon allotrope materials (i.e. carbon nanotubes (CNTs), graphene, graphene oxide (GO)), have been used to reinforce acrylic bone cement. Nevertheless, the intrinsic incompatibility among the above materials produces a deficient interphase. Thus, in this work, the effect of the content of functionalized graphene oxide with a reactive silane on the mechanical properties and cell adhesion of acrylic bone cement was studied. GO was obtained by an oxidative process on natural graphite; subsequently, GO was functionalized with 3-methacryloxypropyltrimethoxysilane (MPS) to enhance the interphase between the graphenic material and acrylic polymeric matrix. Pristine GO and functionalized graphene oxide (GO-MPS) were characterized physicochemically (XPS, XRD, FTIR, and Raman) and morphologically (SEM and TEM). Silanized GO was added into the acrylic bone cement at different concentrations; the resulting materials were characterized mechanically, and their biocompatibility was also evaluated. The physicochemical characterization results showed that graphite was successfully oxidized, and the obtained GO was successfully functionalized with the silane coupling agent (MPS). SEM and TEM images showed that the GO is composed of few stacked layers. Compression testing results indicated a tendency of increasing stiffness and toughness of the acrylic bone cements at low concentration of functionalized GO. Additionally, the bending testing results showed a slightly increase in bone cement strain with the incorporation of GO-MPS. Finally, all samples exhibited cell viability higher than 70%, which means that materials are considered non-cytotoxic, according to the ISO 10993-5 standard.


Assuntos
Grafite , Nanotubos de Carbono , Polimetil Metacrilato/química , Grafite/química , Teste de Materiais , Silanos , Cimentos Ósseos/farmacologia , Cimentos Ósseos/química
13.
Biomed Microdevices ; 26(1): 6, 2023 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-38141082

RESUMO

PMMA-based microfluidics have been widely used in various applications in biological and chemical fields. In the fabrication process of PMMA-based microfluidics, the substrate and cover plate usually need to be bonded to enclose the microchannel. The bonding process could be permanent or reversible. In some application scenarios, reversible bonding is needed to retrieve the samples inside the channel or reuse the chip. Current reversible bonding methods for PMMA-based microfluidics usually have drawbacks on bonding strength and contaminations from the adhesives used in the bonding process. In this study, a new approach is proposed for the reversible bonding of PMMA-based microfluidics, a layer of PBMA (with a very similar structure to PMMA) was coated on the surface of PMMA and then use the thermal fusion method to achieve the bonding with a high bonding strength, a tensile bonding strength of around 0.8 MPa was achieved. For debond process, a rapid temperature drop will trigger the immediate release of the bonding within several seconds. Detailed bonding strength measurement and biocompatibility tests were also conducted in this study. The proposed bonding method could have wide application potential in the fabrication of PMMA-based microfluidics.


Assuntos
Microfluídica , Polimetil Metacrilato , Polimetil Metacrilato/química , Microfluídica/métodos , Dispositivos Lab-On-A-Chip , Temperatura
14.
J Mech Behav Biomed Mater ; 148: 106218, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37931550

RESUMO

Loosening and infection are the main reasons for revision surgery in total hip arthroplasty (THA). Removing partially detached cemented implant components during revision surgery remains challenging and poses the risk of periprosthetic bone damage. A promising approach for a gentler removal of partially detached prostheses involves softening the PMMA-based bone cement by heating it above its glass transition temperature (TG), thus loosening the implant-cement bond. It is assumed that the TG of PMMA-based bone cement decreases in-vivo due to the gradual absorption of body fluid. Reliable data on TG are essential to develop a heat-based method for removing cemented implant components during revision surgery. The effect of water absorption was investigated in-vitro by ageing PMMA-based bone cement samples for different periods up to 56 days in both Ringer's solution (37 °C) and air (37 °C and 30% humidity). Subsequently, the TG and Vicat softening temperatures of the samples were determined by differential scanning calorimetry and Vicat tests, respectively, according to prescribed methods. Over the entire ageing period, i.e. comparing one day of ageing in air and 56 days in Ringer's solution, the Vicat softening temperature dropped by 16 °C, while the TG dropped by 10 °C for Palacos® R PMMA-based bone cement. Water absorption over time correlated significantly with the Vicat softening temperature until saturation of the PMMA-based bone cement was reached. Based on the TG and Vicat softening temperature measurements, it can be assumed that in body-aged bone cement, an optimal softening can be achieved within a temperature range of 85 °C-93 °C to loosen the bond between the PMMA-based bone cement mantle and the prosthesis stem. These findings may pave the way for a gentler removal of the implant in revision THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Cimentos Ósseos/química , Polimetil Metacrilato/química , Reoperação/métodos , Solução de Ringer , Água
15.
Photobiomodul Photomed Laser Surg ; 41(11): 608-621, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37910776

RESUMO

Objective: This systematic review and meta-analysis aimed to assess the influence of laser treatment on adhesive bonding of liners to polymethyl methacrylate (PMMA) denture base resins. Methods: The focused question was: "Does the application of laser treatment (Intervention) influence the adhesive bonding strength (Outcome) of liners to PMMA denture base resins (Population) as compared with untreated or unconditioned surfaces (Control)?" In vitro and clinical reports as well as reports on influence of laser treatments on bonding strength of liners to PMMA denture resins in comparison with untreated surfaces were included. Reports without any control group[s], without any application of laser[s] for PMMA denture bases that did not utilize PMMA denture bases, and not evaluate bond strength of PMMA denture base resins were excluded. An electronic search was conducted on PubMed, Scopus, and Web of Science. Meta-analyses were performed for calculating the standard mean difference (SMD) with a 95% confidence interval (95% CI). Results: Nine of the 12 included studies found that laser irradiation treatment produced significant surface texture alterations of the PMMA denture base and improved the adhesion between the PMMA denture base and soft lining. According to the meta-analysis, tensile bond strength showed an SMD of -2.49% (95% CI: -3.89 to -1.08; p = 0.0005), suggesting a statistically significant difference between the control and test groups (i.e., favoring laser-treated samples than untreated samples). Regarding shear bond strength scores, the outcomes showed an SMD of -2.24% (95% CI: -3.79 to -0.69; p = 0.005), suggesting a statistically significant difference between the control and test groups (i.e., favoring laser-treated samples than untreated samples). Conclusions: Despite the high heterogeneity among the included studies, it can be concluded that laser treatment might improve the bonding strengths of liners to PMMA denture base resins as compared with untreated surfaces. To validate the aforementioned conclusions, further verification is required through the implementation of well-designed randomized controlled trials with large sample sizes.


Assuntos
Reembasadores de Dentadura , Polimetil Metacrilato , Polimetil Metacrilato/química , Adesivos , Resinas Acrílicas/química , Teste de Materiais , Bases de Dentadura
16.
Orthopadie (Heidelb) ; 52(12): 943-956, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37831091

RESUMO

PMMA-based bone cements are used for anchoring artificial joints. The cements are offered as two-component systems. During mixing, a liquid paste is formed by free-radical polymerization, which completely hardens into a solid cement matrix as polymerization progresses with an increase in viscosity. Polymerization from MMA to PMMA is an exothermic process, energy is released in the form of heat. After fixation of the prosthesis and curing of the cement, the cement fills the space between the prosthesis and the bone. With the filler PMMA, a strong force-locking and interlocking mechanical bond is created. The essential properties of PMMA cements are dictated by the powder component. In vivo, the hard and brittle bone cements absorb body fluids and become more elastic and softer. The properties of various PMMA bone cements differ significantly, although the chemical acrylate base is identical.


Assuntos
Cimentos Ósseos , Polimetil Metacrilato , Cimentos Ósseos/química , Polimetil Metacrilato/química , Teste de Materiais , Temperatura Alta , Implantação de Prótese
17.
Lab Chip ; 23(19): 4245-4254, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37655654

RESUMO

Chitosan (CS) is a natural polymer that exhibits many biological properties and is used as a biomaterial for antibacterial coatings, tissue engineering, cell research, drug delivery, and negatively charged molecule capture. In our previous study, we used a CS-polydopamine mixture to realize UV-assisted bonding between poly(methyl methacrylate) (PMMA) substrates to fabricate microdevices for self-assembled stem cell spheroid cultures. Herein, we attained reliable adhesive bonding between PMMAs using CS at room temperature assisted by oxygen plasma. The bond strength of adhesion was as high as 2.1 MPa, which could be stable for over two months according to the leak test. The adhesive bonding and surface functionalization of the microchannels were simultaneously completed such that the microdevices could be directly used for mesenchymal stem cell culture for spheroid generation and DNA purification for point-of-care testing (POCT) devices. Surface characterization was performed by contact angle measurements, Fourier-transform infrared spectroscopy, scanning electron microscopy, and atomic force microscopy. The POCT device allows sequential on-chip DNA purification, amplification, and colorimetric detection of pathogenic bacteria. This method provides a convenient and reliable strategy for the fabrication of PMMA microdevices that can be directly implemented in biological studies and POCT applications without involving prior surface modification steps.


Assuntos
Quitosana , Quitosana/química , Polimetil Metacrilato/química , Materiais Biocompatíveis/química , Antibacterianos/química , DNA , Propriedades de Superfície
18.
Environ Sci Pollut Res Int ; 30(50): 109250-109265, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37759061

RESUMO

The antibacterial activity of a variety of modified poly(methyl methacrylate) Schiff bases against common microbial infections and removal of methylene blue (MB) dye were screened. The Schiff bases were synthesized from the reaction of the modified (PMMA) with vanillin (PMMA)Van and cinnamaldehyde (PMMA)Cin. By using Fourier transformer infrared (FT-IR), X-ray diffraction analysis (XRD), thermogravimetric analysis (TGA), and scanning electron microscopy (SEM), the structures of the nanofibers of the synthesized Schiff bases were confirmed. The modified Kirky-Bauer method was used to screen the antibacterial activities of all the obtained materials against various bacterial species, including gram-positive bacterial (Bacillus subtilis (4k1p), Staphylococcus aureus), Gram-negative bacteria (Escherichia coli (7ab3), Pseudomonas aeruginosa). Inhibition zones against gram-positive bacteria ranged in diameter from 7 to 14 mm, whereas for the Gram-negative bacteria, the inhibition zones found to be ranged between 6 and 13 mm. With a minimum bactericidal concentration (MBC) of 8 mg/mL and a minimum inhibitory concentration (MIC) of 2 mg/mL, (PMMA)Van shown the greatest antibacterial activity. Lastly, molecular docking research was done to better understand the interactions between this series' targets and inhibitors for (PMMA)Van and (PMMA)Cin (4k1p and 7ab3). Molecular modeling of these surface-adsorbed polymers indicated that (PMMA)Van binds more strongly with Nitrogen than does (PMMA)Cin through extra hydrogen-bonding interactions. All the developed materials were evaluated for the removal of 0.1 g/L methylene blue dye (MB) from an aqueous solution. The elimination percentage of MB dye ranged from 26.67% by using 0.05 g powder of (PMMA)Cin to 85.63% by employing 0.05 g nanofibers of (PMMA)Van.


Assuntos
Polimetil Metacrilato , Bases de Schiff , Polimetil Metacrilato/química , Simulação de Acoplamento Molecular , Bases de Schiff/química , Espectroscopia de Infravermelho com Transformada de Fourier , Azul de Metileno/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Polímeros , Testes de Sensibilidade Microbiana
19.
Acta Biomater ; 170: 415-426, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37625677

RESUMO

Candida albicans is an opportunistic yeast and the primary etiological factor in oral candidiasis and denture stomatitis. The pathogenesis of C. albicans could be triggered by several variables, including environmental, nutritional, and biomaterial surface cues. Specifically, biomaterial interactions are driven by different surface properties, including wettability, stiffness, and roughness. Dental biomaterials experience repetitive (cyclic) stresses from chewing and biomechanical movements. Pathogenic biofilms are formed over these biomaterial surfaces under cyclic strain. This study investigated the effect of the cyclic strain (deformation) of biomaterial surfaces on the virulence of Candida albicans. Candida biofilms were grown over Poly (methyl methacrylate) (PMMA) surfaces subjected to static (no strain) and cyclic strain with different levels (ε˜x=0.1 and 0.2%). To evaluate the biomaterial-biofilm interactions, the biofilm characteristics, yeast-to-hyphae transition, and the expression of virulent genes were measured. Results showed the biofilm biomass and metabolic activity to be significantly higher when Candida adhered to surfaces subjected to cyclic strain compared to static surfaces. Examination of the yeast-to-hyphae transition showed pseudo-hyphae cells (pathogenic) in cyclically strained biomaterial surfaces, whereas static surfaces showed spherical yeast cells (commensal). RNA sequencing was used to determine and compare the transcriptome profiles of cyclically strained and static surfaces. Genes and transcription factors associated with cell adhesion (CSH1, PGA10, and RBT5), biofilm formation (EFG1), and secretion of extracellular matrix (ECM) (CRH1, ADH5, GCA1, and GCA2) were significantly upregulated in the cyclically strained biomaterial surfaces compared to static ones. Genes and transcription factors associated with virulence (UME6 and HGC1) and the secretion of extracellular enzymes (LIP, PLB, and SAP families) were also significantly upregulated in the cyclically strained biomaterial surfaces compared to static. For the first time, this study reveals a biomaterial surface factor triggering the pathogenesis of Candida albicans, which is essential for understanding, controlling, and preventing oral infections. STATEMENT OF SIGNIFICANCE: Fungal infections produced by Candida albicans are a significant contributor to various health conditions. Candida becomes pathogenic when certain environmental conditions change, including temperature, pH, nutrients, and CO2 levels. In addition, surface properties, including wettability, stiffness, and roughness, drive the interactions between Candida and biomaterials. Clinically, Candida adheres to biomaterials that are under repetitive deformation due to body movements. In this work, we revealed that when Candida adhered to biomaterial surfaces subjected to repetitive deformation, the microorganism becomes pathogenic by increasing the formation of biofilms and the expression of virulent factors related to hyphae formation and secretion of enzymes. Findings from this work could aid the development of new strategies for treating fungal infections in medical devices or implanted biomaterials.


Assuntos
Candida albicans , Micoses , Humanos , Candida albicans/genética , Virulência/genética , Polimetil Metacrilato/química , Fatores de Transcrição/metabolismo , Metacrilatos/farmacologia , Materiais Biocompatíveis/farmacologia , Biofilmes
20.
Acta Chir Orthop Traumatol Cech ; 90(3): 188-197, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37395426

RESUMO

PURPOSE OF THE STUDY Infections of joint replacements represent one of the most serious problems in contemporary orthopedics. The joint infections treatment is usually multimodal and involves various combinations of drug delivery and surgical procedures. The aim of this study was to evaluate and compare the bacteriostatic and bactericidal properties of the most common antibiotic carriers used in orthopedic surgery: bone cements mixed with antibiotic and porous calcium sulfate mixed with antibiotic. MATERIAL AND METHODS Three commercial bone cements (Palacos®, Palacos® R+G, Vancogenx®) and commercial porous sulfate (Stimulan®) were prepared with a known concentration of vancomycin (a glycopeptide antibiotic). Specifically, for the purpose of our study, the testing specimens were prepared to release 0, 1, 2, 4, 8, 16, 32, 64, 128, 256, and 512 mg of vancomycin into 1 liter of solution. The specimens with increasing amount of antibiotic were placed in a separate tubes containing 5 mL of Mueller-Hinton broth inoculated with a suspension (0.1 m, McFarland 1) of the reference strain CCM 4223 Staphylococcus aureus to evaluate their bacteriostatic properties (broth dilution method). After this initial incubation and evaluation of the broth dilution method, an inoculum from each tube was transferred onto blood agar plates. After another 24-hour incubation under the same conditions, we evaluated the bactericidal properties (agar plate method). As many as 132 of independent experiments were performed (4 specimens × 11 concentrations × 3 repetitions = 132). RESULTS The bacteriostatic properties of all investigated samples were excellent, perhaps with the exception of the first bone cement (Palacos®). The sample Palacos® started to exhibit bacteriostatic properties at concentrations ≥ 8 mg/mL, while all other samples (Palacos R+G®, Vancogenx®, and Stimulan®) were bacteriostatic in the whole concentration range starting from 1 mg/mL. The bacteriocidic properties did not show such clear trends, but correlated quite well with different properties of the investigated samples during mixing - the most homogeneous samples seemed to exhibit the best and the most reproducible results. DISCUSSION The reliable and reproducible comparison of ATB carriers is a difficult task. The situation is complicated by high numbers of local antibiotic carriers on the market, numerous antibiotics used, and differences in clinical trials at different laboratories. Simple in vitro testing of bacteriostatic and bacteriocidic properties represents a simple and efficient approach to the problem. CONCLUSIONS The study confirmed that the two most common commercial systems used in the orthopedic surgery (bone cements and porous calcium sulfate) prevent bacterial growth (bacteriostatic effect), but they may not be 100% efficient in complete elimination of bacteria (bacteriocidic effect). The scattered results in the case of bacteriocidic tests seemed to be connected with the homogeneity of ATB dispersion in the systems and with the lower reproducibility of the employed agar plate method. Key words: local release of antibiotics; bone cements; calcium sulfate; antimicrobial susceptibility.


Assuntos
Procedimentos Ortopédicos , Ortopedia , Humanos , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Sulfato de Cálcio , Vancomicina/farmacologia , Cimentos Ósseos/farmacologia , Cimentos Ósseos/uso terapêutico , Ágar , Reprodutibilidade dos Testes , Polimetil Metacrilato/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...